Luminor Lámpara UV de repuesto RL-720A para sistema ultravioleta LR5/6-552, LR5/6-1102
Q&As
Part Number:RL-720A
Lámpara UV de repuesto con llave que mantiene la salida adecuada para Luminor LR5-552, LR6-552, LR5-1102, LR6-1102.
Read More
Subscription Details ⓘ
Automatic deliveries and charges at your selected frequency. Skip, reschedule, or cancel through your subscription account. View subscription details.
$509.23$636.54
IN STOCK
Case Discount:
Descripción
Esta es una lámpara de repuesto y llave Luminor RL-720A genuina para los sistemas de purificación de agua ultravioleta Luminor LR5-552, LR6-552, LR5-1102, LR6-1102.
La RL-720A es una lámpara LUMINOR auténtica y tiene una vida útil de 9000 horas. La luz UV-C emitida se debilitará con el tiempo, por lo que una vez que una lámpara alcanza las 9000 horas (o cada 12 meses), es importante reemplazar la bombilla de inmediato.
Por qué es importante usar una lámpara LUMINOR genuina: Los sistemas y lámparas UV LUMINOR se prueban y certifican como una unidad completa. El uso de lámparas que no son LUMINOR anula todas las certificaciones del sistema UV y puede comprometer su garantía en caso de que surja un problema.
Garantía: Protección de garantía de reemplazo completa de un año, sin complicaciones.
Specs
Sustituir cada 12 meses o 12.000 horas de uso.
Longitud: 720 mm (28,4 pulgadas)
Potencia: 152 vatios
Features
Incluye llave para lámpara (válida únicamente para sistemas de la marca LUMINOR).
Para todos los sistemas UV LUMINOR LR5-552, LR6-552, LR5-1102, LR6-1102
Helpful Info & Downloads
Downloads
See how to replace the LUMINOR RL-720A UV lamp and reset the lamp-life countdown. The genuine LUMINOR RL-720A fits RAINIER light commercial LR5-555, LR6-555, LR5-555-50, LR6-555-50, LR5-1105, LR6-1105, LR5-1105-50, LR6-1105-50. Rated for 12,000 hours (roughly 16 months), the lamp should be replaced at the end of its rated life to maintain UV output.
Más información del producto
Q:
How do I know if the RL-720A is the right lamp for my system?
A:
Check the model number on your system's nameplate. The RL-720A fits LR5-555, LR6-555, LR5-1105, LR6-1105, and their low-UVT "-50" variants. If your model has a "LB" or "LBH" prefix instead of "LR," you have a BLACKCOMB system and need a different lamp.
Q:
What's the difference between the "-555" and "-1105" Rainier systems?
A:
Both are light commercial systems rated at 30 mJ/cm² and 95% UVT, but at different flow rates: the "-555" tier runs 55 GPM through a single-lamp chamber with 2" MNPT connections, while the "-1105" tier runs 140 GPM through a dual-lamp chamber with 2.5" MNPT connections. The higher flow rating is why the "-1105" systems need two RL-720A lamps instead of one.
Q:
What does the "-50" suffix mean on models like LR5-555-50 or LR6-1105-50?
A:
It marks a low-UVT crossover configuration, built for source water with reduced UV transmittance. Standard "-555" and "-1105" systems are rated for 95% UVT; the "-50" variants deliver the same UV dose at 50% UVT, with flow reduced accordingly, 23 GPM for the "-555-50" tier and 39 GPM for the "-1105-50" tier. They use the same RL-720A lamp as the standard systems.
Q:
My LR5-1105 or LR6-1105 system takes two lamps. Do I need to replace both at the same time?
A:
Luminor recommends replacing both lamps together, even if only one has failed. Since both lamps age at roughly the same rate, replacing them as a pair keeps UV output balanced across the chamber and avoids a second service call soon after the first.
Q:
Will a non-Luminor replacement lamp work in my Rainier system?
A:
It may physically fit, but Luminor systems are certified as a complete lamp-and-system unit. A non-Luminor lamp voids that certification and can affect your warranty if an issue comes up.