Luminor Kit de lámpara UV y funda RLQ-850 para LB4-201, LB5-201, LB6-201
Q&As
Part Number:RLQ-850
El kit de lámpara UV y funda con llave de reinicio restaura la potencia UV y la protección de la funda para los modelos LB4 201, LB5 201 y LB6 201.
Read More
Automatic deliveries and charges at your selected frequency. Skip, reschedule, or cancel through your subscription account. View subscription details.
$178.88$223.60
IN STOCK
Case Discount:
Descripción
El RLQ-850 incluye la lámpara UV de repuesto, el manguito de cuarzo que la acompaña y la llave de la lámpara para los sistemas de tratamiento de agua UV LUMINOR BLACKCOMB modelo LB4-201, LB5-201 y LB6-201. Reemplazar la lámpara cada 12 meses es extremadamente importante para mantener la eficacia adecuada del sistema. El manguito se puede reemplazar cada 24 meses o según sea necesario para evitar que la acumulación de minerales obstaculice la eficacia de la lámpara.
Por qué es importante utilizar una lámpara LUMINOR genuina: Los sistemas y lámparas UV de LUMINOR se prueban y certifican como una unidad completa. El uso de una lámpara LUMINOR auténtica garantiza el rendimiento adecuado del sistema. El uso de lámparas que no son LUMINOR anula todas las certificaciones del sistema UV y puede comprometer su garantía si surge algún problema.
Specs
Incluye RL-850 y RQ-850
Reemplace la lámpara cada 12 meses
Reemplace la funda cada 24 meses o según sea necesario
Features
Incluye llave para lámpara (válida únicamente para sistemas de la marca LUMINOR).
Para todos los LUMINOR BLACKCOMB LB4-201, LB5-201, LB6-201
See how to replace the LUMINOR RLQ-850 UV lamp and quartz sleeve and reset the lamp-life countdown. This genuine LUMINOR kit fits BLACKCOMB LB4-201, LB5-201, LB6-201. The lamp is rated for 9,000 hours (about 12 months), and the quartz sleeve should be replaced every 24 months or sooner if scaled, cloudy, or damaged.
Más información del producto
Q:
What is the Luminor RLQ-850 UV Lamp and Sleeve Kit?
A:
It's a matched replacement kit for Luminor BLACKCOMB UV water treatment systems, including a genuine RL-850 UV lamp, RQ-850 quartz sleeve, and installation key — everything needed to replace both wear parts in one order.
Q:
Is a UV bulb the same thing as the RL-850 lamp?
A:
Yes. "UV bulb" and "UV lamp" refer to the same part — the RL-850 is the UV lamp (sometimes called a UV bulb) included in this kit.
Q:
How often do I need to replace the lamp and sleeve?
A:
Luminor recommends replacing the RL-850 lamp every 12 months (or after 9,000 hours), and the RQ-850 sleeve every 24 months. Replacing both together on the lamp's schedule keeps UV output consistent and simplifies maintenance timing.
Q:
Can I order the lamp and sleeve separately instead of as a kit?
A:
Yes. If only one part needs replacing, the RL-850 lamp and RQ-850 quartz sleeve are each available on their own. The RLQ-850 kit is for when you're replacing both at once, which is the recommended approach since both wear parts age together.
Q:
My system alarm says "Connection Failure" — what does that mean?
A:
This alarm usually means a module, sensor, or lamp key isn't securely connected, or a connection port is dirty or damaged. Unplug the controller, check that all connections (including the lamp key) are secure, then wait a minute before plugging it back in. If the alarm continues, contact Luminor support for further assistance.
Luminor Kit de lámpara UV y funda RLQ-850 para LB4-201, LB5-201, LB6-201