Tubo de cuarzo UV de repuesto Luminor RQ-950 para LBH4-401, LBH5-401, LBH6-401

Q&As

Tubo de cuarzo UV de repuesto Luminor RQ-950 para LBH4-401, LBH5-401, LBH6-401

Q&As
Part Number: RQ-950
El manguito de cuarzo de repuesto protege la lámpara UV y asegura una salida adecuada para los sistemas LBH4-401, LBH5-401, LBH6-401. Read More
This Item Fits Select Systems
See List
$96.29$120.36
SHIPS IN 3-4 SEMANAS
Descripción

Esta es una funda de cuarzo de repuesto original Luminor Blackcomb RQ-950 para los sistemas de desinfección ultravioleta Luminor LBH4-401, LBH5-401, LBH6-401.

Esta funda de cuarzo evitará que la lámpara UV RQ-950 sufra cortocircuitos y ayuda a mantener la temperatura de funcionamiento ideal de la lámpara UV.

La acumulación de minerales dificulta la eficacia de la lámpara y debe limpiarse regularmente. Las fundas de cuarzo UV deben reemplazarse cuando estén astilladas, agrietadas o permanezcan descoloridas incluso después de la limpieza.

Garantía: Protección de garantía completa de reemplazo sin problemas de un año.

Specs
  • Reemplazar cada 24 meses o según sea necesario.
  • Longitud: 996 mm (39,21 pulgadas)
  • Estilo: abovedado
Features
Para usar con los sistemas UV LUMINOR BLACKCOMB LBH4-401, LBH5-401, LBH6-401.
This Item Fits These Select Systems
Helpful Info & Downloads
Downloads

Watch this step-by-step video to learn how to replace a quartz sleeve on a Luminor UV water treatment system for optimal UV disinfection performance. ESP Water Products, an authorized Luminor dealer, offers genuine Luminor UV systems and replacement parts.

Q:

Does the RQ-950 fit the HW, -50, and TOC versions of my system, or just the standard LBH-401?

A:

It fits all of them. The HW, low-UVT ("-50"), and TOC variants of the LBH4/5/6-401 all use the same chamber and sleeve as the standard system; only the lamp and the system's internal dose settings change between variants.

Q:

How do I know if I need to clean the sleeve or replace it?

A:

Clean it if it's scaled or lightly stained; replace it if it's scratched, pitted, or stays cloudy after cleaning. Even with no visible damage, Luminor recommends replacing the sleeve every 24 months as routine maintenance, since UV-C transmission through quartz declines gradually with age.

Q:

Do I need to buy the lamp too, or can I just replace the sleeve?

A:

The RQ-950 is the sleeve only. If your lamp is also due, pair it with the [RL-950HO](https://espwaterproducts.com/products/luminor-rl-950ho-replacement-uv-lamp-for-lbh4-401-lbh5-401-lbh6-401) lamp, or save by ordering the [RLQ-950HO](https://espwaterproducts.com/products/luminor-rlq-950ho-uv-lamp-and-sleeve-kit-for-lbh4-401-2-lbh5-401-2-lbh6-401-2) kit, which bundles both.

Q:

Can I use a non-Luminor sleeve instead of the RQ-950?

A:

You can, but it's not recommended. Luminor certifies its systems as a complete lamp-chamber-sleeve unit, and a non-Luminor sleeve can differ in wall thickness or quartz quality, which reduces the UV-C dose reaching the water and can affect your warranty coverage.

Q:

Why does my TOC or HW system need a different lamp but the same sleeve?

A:

The TOC and HW variants change the dose and wavelength the lamp delivers, which needs a different lamp built for that job. The sleeve's role is just to protect the lamp and let UV-C pass through to the water, so its design doesn't need to change between variants.