Service was great
"Service was great"
Lámpara UV VIQUA S740RL-HO para SPV-15, SP740-HO, SC-740
Automatic deliveries and charges at your selected frequency. Skip, reschedule, or cancel through your subscription account. View subscription details.
Esta lámpara es el repuesto para los sistemas UV obsoletos de la serie VIQUA Sterilight SPV-15, SPV-740, SP740-HO, SC-740 y SCM-740. Es extremadamente importante reemplazar esta lámpara cada 12 meses para mantener la eficacia adecuada del sistema.
Por qué es importante utilizar una lámpara VIQUA original: Los sistemas UV y las lámparas VIQUA son probados y certificados como una unidad completa. El uso de una lámpara VIQUA auténtica garantiza el rendimiento adecuado del sistema y el tratamiento del agua. Este video explica los 5 riesgos de las lámparas de repuesto que no son VIQUA y cómo identificar las lámparas VIQUA auténticas.
NOTA: El uso de lámparas que no son VIQUA anula todas las certificaciones del sistema UV y puede comprometer su garantía si surge algún problema.
Overall rating: 5.0 / 5 from 1 reviews.
Review topics: [].
"Service was great"
Q:
Which systems use the VIQUA S740RL-HO?
A:
The catalog does not provide an approved model list for VIQUA S740RL-HO. Match the exact part number, dimensions, connection style, and equipment generation before ordering.
Q:
How often should the VIQUA S740RL-HO be replaced?
A:
Replace it every 12 months, even if it still lights. UV output declines with operating time, so visible light does not confirm expected treatment output.
Q:
Does this listing include a quartz sleeve?
A:
No. This is the replacement lamp only unless package contents explicitly state otherwise. Inspect the sleeve and seals during lamp service.
Q:
Why is the exact lamp part number important?
A:
Lamp length, base, wattage, and UV output must match the controller and chamber. The associated Sterilight systems are obsolete, so exact lamp and connector matching is essential.
Q:
What should I do before changing the lamp?
A:
Turn off power, shut off water if the chamber will be opened, relieve pressure, allow the lamp to cool, and handle the replacement with clean gloves.
Q:
What should I check after installation?
A:
Confirm connector alignment, controller operation, lamp-life reset, sleeve condition, and leak-free seals before returning the system to normal operation.