★★★★★ Sirviendo a más de 60.000 clientes con más de 6.200 reseñas de cinco estrellas.
Find Replacements
FILTER FINDER

What system do you have?

Brand
Select your brand...
Model
Select your model...

Luminor RL-470 Lámpara UV de repuesto para LB4-061, LB5-061, LB6-061

Q&As

Luminor RL-470 Lámpara UV de repuesto para LB4-061, LB5-061, LB6-061

Q&As
Part Number: RL-470
Lámpara UV de repuesto con llave de reinicio que restaura 9000 horas de rendimiento para los sistemas Luminor LB4 061, LB5 061 y LB6 061. Read More
This Item Fits Select Systems
See List
$97.23$121.54
IN STOCK
Receive a 16% bulk discount   on orders of 12 or more
Descripción

Esta lámpara UV es la lámpara de repuesto y la llave para los sistemas de tratamiento de agua UV LUMINOR BLACKCOMB LB4-061, LB5-061 y LB6-061.

La RL-470 es una lámpara LUMINOR auténtica y tiene una vida útil de 9000 horas. La luz UV-C emitida se debilitará con el tiempo, por lo que una vez que una lámpara alcanza las 9000 horas (o cada 12 meses), es importante reemplazar la bombilla rápidamente.

Por qué es importante usar una lámpara LUMINOR original: Los sistemas y lámparas UV de LUMINOR se prueban y certifican como una unidad completa. El uso de una lámpara LUMINOR auténtica garantiza el rendimiento adecuado del sistema. El uso de lámparas que no son LUMINOR anula todas las certificaciones del sistema UV y puede comprometer su garantía en caso de que surja un problema.

Mantenga su sistema de tratamiento de agua UV Luminor Blackcomb funcionando a su máximo rendimiento con la lámpara UV de repuesto original Luminor RL-470. Diseñada para las series Blackcomb LB4-061, LB5-061 y LB6-061, esta lámpara UV de baja presión (LP) de alta calidad ofrece una salida de desinfección constante y confiable durante toda su vida útil nominal de 9,000 horas, gracias a su revestimiento interno avanzado que evita la degradación de la salida con el tiempo.

A diferencia de las lámparas UV estándar que pierden intensidad a medida que envejecen, el revestimiento interno de la RL-470 mantiene una salida UV uniforme desde el primer uso hasta la última hora, asegurando que su agua siempre sea tratada con el mismo alto estándar. La base de la lámpara de cerámica de alta resistencia agrega una capa adicional de durabilidad e integridad estructural, protegiendo su inversión y manteniendo un sello seguro dentro de su sistema.

El reemplazo es rápido y sencillo. La RL-470 está diseñada para funcionar sin problemas con el sistema de llave de lámpara encriptada de Luminor, agregando una capa adicional de protección contra la instalación incorrecta o no autorizada de la lámpara. Cada lámpara se envía con una junta tórica incluida, por lo que no se requieren piezas adicionales; simplemente cambie la lámpara vieja y estará de nuevo en funcionamiento.

No comprometa la calidad del agua: reemplace su lámpara UV a tiempo y mantenga su sistema funcionando exactamente como debe.

Specs
  • Sustituir cada 12 meses o 9.000 horas de uso.
  • Longitud: 470 mm (18,5 pulgadas)
  • Potencia: 22 vatios
Features
Incluye llave de lámpara (funciona solo para sistemas de la marca LUMINOR)
Para todos los modelos LUMINOR BLACKCOMB 4.1 LB4-061, 5.1 LB5-061, 6.1 LB6-061
Helpful Info & Downloads
Downloads

Watch this step-by-step video to learn how to replace a quartz sleeve on a Luminor UV water treatment system for optimal UV disinfection performance. ESP Water Products, an authorized Luminor dealer, offers genuine Luminor UV systems and replacement parts.

Overall rating: 5.0 / 5 from 4 reviews.

AI Generated Review Summary

Summary topics

Review topics: [].

Review highlights

Reviews

Exactly Right

"The lamp arrived on time, very well-packaged, and worked perfectly as soon as we installed it. It was easy enough to do that I installed it myself instead of waiting for the plumber we hired. It would be nice if there was a warning on the package (say, on the tube) to only touch the base of the lamp and not the glass. I pulled the lamp out, and it was intuitive to grab the glass to do so. That meant I needed to clean it carefully before install. Maybe you can learn from my mistake."

Hope M. (5/5)

replacement lamp

"fit well - easy to install - easy to reset timer"

Guido M. (5/5)

Quick Shipment

"This bulb was needed by one of our customers, but difficult to find. ESP had availability and shipped quickly."

Jerry M. (5/5)

Excellent service

"Excellent service"

Peter H. (5/5)

Q&A

Overall rating: 5.0 / 5 from 4 reviews.

AI Generated Review Summary

Summary topics

Review topics: [].

Review highlights

Reviews

Exactly Right

"The lamp arrived on time, very well-packaged, and worked perfectly as soon as we installed it. It was easy enough to do that I installed it myself instead of waiting for the plumber we hired. It would be nice if there was a warning on the package (say, on the tube) to only touch the base of the lamp and not the glass. I pulled the lamp out, and it was intuitive to grab the glass to do so. That meant I needed to clean it carefully before install. Maybe you can learn from my mistake."

Hope M. (5/5)

replacement lamp

"fit well - easy to install - easy to reset timer"

Guido M. (5/5)

Quick Shipment

"This bulb was needed by one of our customers, but difficult to find. ESP had availability and shipped quickly."

Jerry M. (5/5)

Excellent service

"Excellent service"

Peter H. (5/5)

Q&A

Q:

How do I know if the RL-470 is the right lamp for my system?

A:

Check the model number on your system's nameplate. The RL-470 fits any Luminor BLACKCOMB system ending in "-061": LB4-061, LB5-061, LB6-061, LB5-061B, LB6-061B, LB6-061A, and LBV-061. If your model ends in a different number, like -021, -031, or -101, you need a different lamp.

Q:

My system is showing a "Lamp Expired" alarm. What does that mean?

A:

t means the lamp has reached the end of its rated life, or a new lamp was installed but the countdown timer on the controller was never reset. Luminor's guidance is that water may not be adequately treated once a lamp has expired, so replace the lamp and reset the timer as soon as possible. Holding the controller button for 5 seconds defers the alarm for 7 days, up to three times, but this doesn't restore UV treatment in the meantime.

Q:

What does a "Lamp Failure" alarm mean?

A:

It means the controller can't light the lamp. Unplug the system for at least 3 minutes, check that the lamp connector is fully seated, then plug it back in. If the alarm continues, replace the lamp. If a new lamp doesn't clear it, the controller itself may need service.

Q:

I installed a new RL-470 and now the system says "Lamp Incorrect." What's wrong?

A:

This alarm means the lamp key doesn't match what your chamber requires. Compare the part number on the lamp key to the silver label on the UV chamber. If they don't match, you have the wrong lamp; the RL-470 is for the standard-output LB4/LB5/LB6-061 systems listed above, and BLACKCOMB-HO systems use an entirely different model and lamp lineup. If the numbers do match and the alarm persists, contact Luminor support.

Q:

How do I reset the lamp timer after installing the RL-470?

A:

On a 4.1 controller (4-digit LED display), press and hold the front button until the display cycles through rSt3, rSt2, rSt1 and beeps. On a 5.1 controller (LCD display with lamp key), unplug the controller, remove the old lamp key, insert the new lamp's key, then plug it back in. Either way, the display should return to showing full lamp life remaining; if it doesn't, contact Luminor support.

Q:

Will a non-Luminor replacement lamp work in my BLACKCOMB system?

A:

It may physically fit, but Luminor systems are NSF/ANSI 55 certified as a complete lamp-and-system unit. A non-Luminor lamp voids that certification and can affect your warranty if an issue comes up.

text

Luminor RL-470 Lámpara UV de repuesto para LB4-061, LB5-061, LB6-061

$97.23$121.54