★★★★★ Sirviendo a más de 89.000 clientes con más de 6.300 reseñas de cinco estrellas.
FILTER FINDER

What system do you have?

Marca
Select your brand...
Modelo
Select your model...

Luminor RL-820 Lámpara UV de repuesto para LB4-101, LB5-101, LB6-101

Q&As

Luminor RL-820 Lámpara UV de repuesto para LB4-101, LB5-101, LB6-101

Q&As
Part Number: RL-820
La lámpara UV de repuesto con llave de reinicio restaura la producción de 9000 horas para los sistemas domésticos completos LB4 101 y LB5 101. Read More
This Item Fits Select Systems
See List
$111.24
IN STOCK

Descripción

La RL-820 es una lámpara UV de repuesto original de Luminor con llave de lámpara para los sistemas de tratamiento de agua UV LUMINOR BLACKCOMB LB4-101, LB5-101 y LB6-101, y sus variantes NSF Class A/B que se indican a continuación. Es una pieza auténtica de Luminor, no un sustituto compatible del mercado de repuestos, por lo que se instala directamente y trata el agua tal como su sistema fue probado y certificado originalmente.

La lámpara tiene una vida útil nominal de 9,000 horas de uso, aproximadamente 12 meses de funcionamiento continuo. La emisión de UV-C se debilita gradualmente a lo largo de la vida de la lámpara, por lo que Luminor recomienda reemplazarla cada 12 meses o después de 9,000 horas, lo que ocurra primero, para mantener la emisión UV en el nivel que el sistema necesita.

Por qué es importante una lámpara Luminor original

Luminor prueba y certifica sus sistemas UV como una unidad completa: lámpara, cámara y funda en conjunto. Una RL-820 auténtica mantiene el rendimiento de su sistema tal como fue certificado. Una lámpara que no sea Luminor anula la certificación NSF/ANSI 55 del sistema y puede afectar la cobertura de su garantía si surge un problema más adelante.

Compatible con estos sistemas Luminor BLACKCOMB

  • LB4-101
  • LB5-101
  • LB6-101
  • LB5-101B (NSF Class B, sin monitoreo)
  • LB6-101B (NSF Class B, sin monitoreo)
  • LB6-101A (NSF Class A, con monitoreo, incluye sensor UV)

Los sufijos A y B indican la clase de monitoreo NSF/ANSI 55 del sistema (A tiene monitoreo con sensor UV, B no tiene monitoreo), no una lámpara diferente. Los seis modelos anteriores comparten la misma clasificación de caudal "-101" y usan la RL-820.

Complete su reemplazo La RL-820 es solo la lámpara. Para el reemplazo completo:

Specs
  • Sustituir cada 12 meses o 9.000 horas de uso.
  • Longitud: 820 mm (32,3 pulgadas)
  • Potencia: 39 vatios
Features
Incluye llave de lámpara (funciona solo para sistemas de la marca LUMINOR)
Para todos los modelos LUMINOR BLACKCOMB 4.1 LB4-101, 5.1 LB5-101, 6.1 LB6-101
Lámpara original Luminor OEM, no un repuesto genérico
Helpful Info & Downloads
Downloads

See how to replace the LUMINOR RL-820 UV lamp and reset the lamp-life countdown. The genuine LUMINOR RL-820 fits BLACKCOMB LB4-101, LB5-101, LB6-101, LB5-101B, LB6-101B, LB6-101A. Rated for 9,000 hours, the lamp should be replaced about every 12 months to maintain UV output.

Luminor RL-820 replacement UV lamp for Blackcomb systems: specs, how UV works, and why genuine lamps matter

Customer Reviews

Overall rating: 4.7647057 / 5 from 17 reviews.

AI Generated Review Summary

Summary topics

Review topics: ["shipping","price","system","service","process","esp"].

Review highlights

Reviews

New bulb

"Bulb works as it should"

— jack b. (5/5)

UV Lamp

"Product came as expected. Had a lamp recently go bad and ESP was very helpful with warranty replacement."

— Wayne N. (5/5)

Bulb arrived broken - ESP not accepting for return

"I have a Luminor LB5-101B system that calls for an RL-820 UV bulb per the unit labeling. I purchased this exact bulb from ESP Water. The bulb arrived at my home from ESP with one filament broken (open circuit using a ohmmeter). ESP claims this is the wrong bulb for my system and the return window has closed. The replacement bulb labeling on my system suggests otherwise. I wasted $111 and I still don't have a functional UV system. Frustrating. Buyer beware. Consider another UV bulb vendor for your replacement bulbs."

— Mark K. (1/5)

Excellent Customer service and Product

"I recently had an issue with one of the lamps that was delivered with my order, so I contacted customer service for assistance. Their response was excellent from start to finish. They were prompt in returning my calls, professional in their communication, and genuinely focused on resolving the problem quickly. After explaining the issue, the team immediately arranged to send me a replacement lamp, and the process was smooth and hassle-free. It’s clear they stand behind their products and truly value their customers. Customer service like this makes a big difference. The responsiveness, follow-through, and overall professionalism exceeded my expectations. I’m very happy with the service I received and would confidently recommend this company to others based on the support experience alone."

— Tom I. (5/5)

Loved it

"Thanks"

— James K. (5/5)

Perfect! So happy to have found you.

"I love this filtering system. Had my water tested amd it times 99 percent of all unwanted contaminates."

— Leslie W. (5/5)

Right part good price

"ESP always has what I need at a decent price."

— jack b. (5/5)

Perfect

"Shipping was quick and bulb worked as expected. I will be ordering again next year."

— Dale L. (5/5)

Good!

"Customer service was excellent!!"

— Leon M. (5/5)

Replacement parts

"Great customer support and promt delivery"

— Fred R. (5/5)

Q&A

Frequently Asked Questions

Q:

How do I know if the RL-820 is the right lamp for my system?

A:

Check the model number on your system's nameplate. The RL-820 fits any Luminor BLACKCOMB system ending in "-101": LB4-101, LB5-101, LB6-101, LB5-101B, LB6-101B, and LB6-101A. If your model ends in a different number, like -061, -151, or -201, you need a different lamp.

Q:

My system is showing a "Lamp Expired" alarm. What does that mean?

A:

It means the lamp has reached the end of its rated life, or a new lamp was installed but the countdown timer on the controller was never reset. Luminor's guidance is that water may not be adequately treated once a lamp has expired, so replace the lamp and reset the timer as soon as possible. Holding the controller button for 5 seconds defers the alarm for 7 days, up to three times, but this doesn't restore UV treatment in the meantime.

Q:

What does a "Lamp Failure" alarm mean?

A:

It means the controller can't light the lamp. Unplug the system for at least 3 minutes, check that the lamp connector is fully seated, then plug it back in. If the alarm continues, replace the lamp. If a new lamp doesn't clear it, the controller itself may need service.

Q:

I installed a new RL-820 and now the system says "Lamp Incorrect." What's wrong?

A:

This alarm means the lamp key doesn't match what your chamber requires. Compare the part number on the lamp key to the silver label on the UV chamber. If they don't match, you have the wrong lamp; the RL-820 is for the standard-output LB4/LB5/LB6-101 systems listed above, and BLACKCOMB-HO systems use an entirely different model and lamp lineup. If the numbers do match and the alarm persists, contact Luminor support.

Q:

How do I reset the lamp timer after installing the RL-820?

A:

On a 4.1 controller (4-digit LED display), press and hold the front button until the display cycles through rSt3, rSt2, rSt1 and beeps. On a 5.1 controller (LCD display with lamp key), unplug the controller, remove the old lamp key, insert the new lamp's key, then plug it back in. Either way, the display should return to showing full lamp life remaining; if it doesn't, contact Luminor support.

Q:

Will a non-Luminor replacement lamp work in my BLACKCOMB system?

A:

It may physically fit, but Luminor systems are NSF/ANSI 55 certified as a complete lamp-and-system unit. A non-Luminor lamp voids that certification and can affect your warranty if an issue comes up.