Luminor LB5-101B Blackcomb 5.1 UV System NSF Class B 13 GPM
Luminor LB5-101B Blackcomb 5.1 UV System NSF Class B 13 GPM
Descripción
The Luminor LB5-101B BLACKCOMB 5.1 is a UV water treatment system certified to NSF/ANSI 55 Class B. With its built-in flow restrictor it is rated at 13 GPM (49.2 L/min) at a UV dose of 16 mJ/cm² and 70% UV transmittance. Class B systems provide supplemental bactericidal treatment of water that is already considered safe to drink, such as treated municipal water, reducing normally occurring non-pathogenic nuisance microorganisms. It uses a 39-watt UV lamp in a polished 304 stainless steel chamber, with 3/4-inch MNPT connections.
How it works and alerts you
The full-colour LCD BLACKCOMB 5.1 controller shows remaining lamp life, diagnostics and fault messages, gives a yellow caution 30 days before the lamp expires and an audible and visual alarm at lamp failure, and shows a service reminder every 6 months. Its Infinite Expandability Port (IEP) accepts an optional RS-B2.5 UV intensity sensor and Luminor modules such as MOD-SOL, MOD-420, MOD-RAM, MOD-SHERPA and the LFM flow meter. The controller reports lamp status; it does not by itself confirm the water is safe to drink, so Luminor recommends testing your water for microbiological contaminants regularly.
Class B vs. Class A
Class B is not intended for water with known contamination. For untreated well water or other microbiologically unsafe supplies, choose an NSF/ANSI 55 Class A system such as the BLACKCOMB-HO 6.1 LBH6-251A or LBH6-401A.
Why the rating is 13 GPM
The standard LB5-101 is rated 11 GPM at 30 mJ/cm² and 95% UVT. The Class B rating uses a lower dose (16 mJ/cm²) at lower water clarity (70% UVT), and the integral flow restrictor holds flow to the certified 13 GPM. Do not remove the flow restrictor.
Water quality requirements
- Luminor strongly recommends a 5-micron sediment prefilter before the UV system
- Hardness under 7 gpg (soften above this); pH 6.5-8.5
- Iron under 0.3 ppm, manganese under 0.05 ppm, tannins under 0.1 ppm, turbidity under 1 NTU
- UV transmittance above 85% (contact Luminor below 80% for pretreatment advice)
Specifications
- Certification: NSF/ANSI 55 Class B
- Certified flow: 13 GPM (49.2 L/min) at 16 mJ/cm², 70% UVT
- Connections: 3/4-inch MNPT
- Lamp: 39 W, RL-820; power draw 49 W
- Electrical: 90-265V, 50/60 Hz; North American NEMA 5-15 plug ("1" suffix)
- Chamber: polished 304 stainless steel, 2.5 x 35.2 inches
- Operating pressure: 10-150 psi; water temperature: 36-149°F (2-65°C)
- UPC: 880027021758
Maintenance and replacement parts
- UV lamp: RL-820. Replace every 12 months (standard lamps are rated about 9,000 hours).
- Quartz sleeve: RQ-820. Clean every 6-12 months and replace every 24 months, or sooner if scaled, cloudy or damaged.
- Lamp and sleeve kit: RLQ-820
- NSF O-ring: 300070
- Optional UV sensor: RS-B2.5
Warranty Luminor limited warranty: 10 years on the stainless steel reactor, 3 years on the controller, and 1 year on UV lamps, UV sensors and quartz sleeves.
- Flow rating: 13 GPM at 16 mJ/cm² and 70% UV transmittance
- 3/4-inch MNPT connections
- 90–265V, 50/60 Hz. North American power-cord configuration.
- Replacement UV lamp: RL-820
- Replacement quartz sleeve: RQ-820
- Application: supplemental disinfection of water that is already potable