The next generation of whole-home and light commercial UV water purification. Engineered for installers and designed for homeowners.
How Arros UV Compares to Traditional UV
Integrated Lamp & Sleeve
Lamp Replaced in Half the Time
No Sleeve Cleaning Required
Zero Tools Needed
System Installed in Half the Time
Plumb Directly to PEX
Best Price Guarantee
US-Based Support
Made in North America
Same Day Shipping
ARROS SERIES—KEY FEATURES AT A GLANCE
Designed for performance, simplicity, and long-term reliability.
Kills bacteria & viruses
NSF certified options
Industry leading warranty
Up to 50% faster installation
Direct PEX pipe compatibility
Vertical or horizontal installation
Compact, space saving design
LCD touchscreen with smart reminders
All-in-one lamp & sleeve
Optional integrated pre- filtration
All-in-one lamp & sleeve
Optional integrated pre- filtration
PRODUCT LINEUP
Choose Your Arros System
Three powerful options to match your exact flow requirements. All systems available in Standard, V-Series, and IHS configurations.
Arros 9
Compact Power
Flow Rate
9 GPM
Power
33W
Size
3" x 14"
Inlet/Outlet
3/4" NPT
Ideal For:
Small homes
Apartments
Cottages
RVs
Available Models:
Standard
V-Series
9-IHS10
9-IHS12
Replacement lamp: VA9LU
Most Popular
Arros 15
Residential Workhorse
Flow Rate
15 GPM
Power
46W
Size
3" x 18"
Inlet/Outlet
3/4" NPT
Ideal For:
Average homes
Multi-bathroom
Small commercial
Offices
Available Models:
Standard
V-Series
15-IHS10
15-IHS12
15-IHS22
Replacement lamp: VA15LU
Arros 22
Maximum Flow
Flow Rate
22 GPM
Power
52W
Size
4" x 22"
Inlet/Outlet
1" NPT
Ideal For:
Large home
Multi-family
Light commercial
Restaurants
Available Models:
Standard
V-Series
22-IHS22
Replacement lamp: VA22LU
Not sure which system is right for you?
Also Available with Integrated Pre-Filtration (IHS)
Why Pre-Filtration Matters for UV Systems
Clear water is essential for effective UV disinfection
UV systems work best when water is clear. Sediment, turbidity, and particles can block UV light and shield microorganisms from exposure—reducing disinfection performance. This is especially important for well water and challenging water conditions.
Protects Your Investment
Sediment filtration prevents buildup on the UV lamp, maintaining proper light transmission and extending system life.
Ensures Proper UV Dosage
Cleaner water allows UV light to effectively inactivate microorganisms year-round.
Simplifies Installation
One integrated system means one footprint, one install, and coordinated maintenance.
Improves Water Quality
Carbon filtration (IHS12 / IHS22) reduces chlorine, taste, odor, and chemical contaminants before UV treatment.
EASIEST MAINTENANCE IN THE INDUSTRY
Annual Lamp Replacement—That's It!
The innovative all-in-one lamp design combines the UV lamp and quartz sleeve in a single unit with one connection. No lamp harness required. Replacement takes minutes, not hours, across all Arros models—whether you have a standard system or an IHS model with pre-filtration.
All-in-One Lamp Units:
Single-piece design
9,000-hour lamp life
Simple annual replacement
Stream™ technology for accurate lamp-life tracking
Quick-Drain Design
The threaded plug allows for fast, clean draining during maintenance. No mess, no fuss.
Smart LCD Touchscreen
The threaded plug allows for fast, clean draining during maintenance. No mess, no fuss.
Auto-Reset Technology
The threaded plug allows for fast, clean draining during maintenance. No mess, no fuss.
PROVEN PROTECTION YOU CAN TRUST
Rigorously tested against the microorganisms that matter most.
Validated Through Microbial Testing
Every VIQUA Arros UV system has been rigorously tested and validated to deliver effective UV dose for inactivating:
- Cryptosporidium
- Giardia
- Escherichia coli (E. coli)
- Fecal coliform
NSF Certified Options Available
Arros V-series models (9-V, 15-V, 22-V) are tested and certified by NSF International against CSA B483.1 and NSF/ANSI 55 for Class B Disinfection Performance.
Universal Operating Parameters
- Maximum Operating Pressure: 125 psi (8.62 bar)
- Ambient Water Temperature: 36-95°F (2-35°C)
- Voltage: 100-240V (50/60 Hz) - Works worldwide
PROVEN PROTECTION YOU CAN TRUST
Rigorously tested against the microorganisms that matter most.
Validated Through Microbial Testing
Every VIQUA Arros UV system has been rigorously tested and validated to deliver effective UV dose for inactivating:
- Cryptosporidium
- Giardia
- Escherichia coli (E. coli)
- Fecal coliform
NSF Certified Options Available
Arros V-series models (9-V, 15-V, 22-V) are tested and certified by NSF International against CSA B483.1 and NSF/ANSI 55 for Class B Disinfection Performance.
Universal Operating Parameters
- Maximum Operating Pressure: 125 psi (8.62 bar)
- Ambient Water Temperature: 36-95°F (2-35°C)
- Voltage: 100-240V (50/60 Hz) - Works worldwide
Compare VIQUA Arros Models
Choose the right VIQUA Arros UV system for your home, available in Standard or Integrated (IHS) models with pre-filtration.
Replacement Parts & Maintenance Kits For Arros UV
Maintain Peak Performance. Annual Lamp Replacement is the only regular maintenance required.
In Stock
VA09LU
Replacement Lamp
- Rated Life: 9,000 Hours (1 Year)
- Design: All-in-One Lamp & Sleeve
- Warranty: 1-Year
Fits Arros 9, 9-V, 9-IHS10, 9-IHS12
In Stock
VA15LU
Replacement Lamp
- Rated Life: 9,000 Hours (1 Year)
- Design: All-in-One Lamp & Sleeve
- Warranty: 1-Year
Fits Arros 15, 15-V, 15-IHS10, 15-IHS12, 15-IHS22
In Stock
VA22LU
UV Lamp
- Rated Life: 9,000 Hours (1 Year)
- Design: All-in-One Lamp & Sleeve
- Warranty: 1-Year
Fits VIQUA Arros 22, 22-V, 22-IHS22 System
In Stock
CMB-520-HF
Replacement Lamp
- 20-inch filter removes dirt, rust, and particulates.
- Every 6-12 Months.
- Essential protection to prevent UV lamp shielding.
IHS12 and IHS22 models.
In Stock
C2-02PB
Carbon Filter
- Removes lead chlorine, taste, and odor.
- Every 6-12 Months.
- Polishes water quality before UV disinfection.
IHS12 and IHS22 models.
In Stock
CMB-510-HF
UV Lamp
- 10-inch filter removes dirt, rust, and particulates.
- Every 6-12 Months.
- Essential protection to prevent UV lamp shielding.
IHS10 and IHS10 models.
TECHNICAL RESOURCES & SUPPORT
Everything you need to install, maintain, and support your Arros system—one place.
Download System Manuals & Guides
Common Questions Before Buying VIQUA Arros UV
What size UV system do I need (Arros 9 vs 15 vs 22)
Your system size will depend on household water usage and flow rate. Larger models (15 & 22) support higher flow and bigger homes. Our customer support team is happy to talk you through system sizing. Call 877-377-9876.
Do I need pre-filtration before UV?
Pre-filtration is often necessary because UV light requires clear water to properly disinfect. Sediment, turbidity, iron, or other particles can block UV penetration and reduce effectiveness. Homes using well water or experiencing visible sediment should strongly consider an IHS (Integrated Home System) model with built-in sediment and carbon filtration.
Does the Arros system remove chemicals or sediment?
UV systems are designed specifically for disinfection and do not remove sediment, hardness, iron, chlorine, or chemical contaminants. UV light neutralizes bacteria, viruses, and protozoa, but it does not filter the water. If contaminant removal is needed, the UV system should be paired with appropriate filtration equipment.
How effective is VIQUA Arros at eliminating pathogens?
The VIQUA Arros UV system is highly effective at inactivating harmful microorganisms when properly sized and maintained. It has been validated through microbial testing to neutralize pathogens such as E. coli, Giardia, Cryptosporidium, and fecal coliform by disrupting their DNA so they cannot reproduce. Certain models are NSF/ANSI 55 Class B certified, confirming tested bacterial reduction performance under controlled conditions. Effectiveness depends on proper installation, water clarity, and annual lamp replacement.
What water clarity is required for proper UV treatment?
For proper UV treatment, the water must be clear enough for UV light to pass through, with low turbidity (typically below 1 NTU) and minimal iron, hardness, or sediment. That’s why pre-filtration is important—cloudy or dirty water can block UV light and reduce disinfection effectiveness.
Why Buy from ESP Water
Real water treatment professionals. Real solutions.
US-Based in Dallas, TX
Certified Water Treatment Specialists
Installation & Technical Support
Same-Day Response
Contact Us
Phone
1-877-377-9876
Mon–Fri, 8am–5pm CST
support@espwater.com
Live Chat
Coming soon
Why Customers Choose Arros Series
Trusted by homeowners and installers for reliability, simplicity, and support.
Verified Customer Reviews
WARRANTY & SUPPORT
Industry-leading coverage backed by real experts.
Industry-Leading Warranty Coverage
Professional Support You Can Trust
Toll-free technical support
1-877-377-9876
Online resources
Manuals & guides available
Online resources
View Warranty Details
We Match or Beat Any Online Price
Found a lower price on your Arros UV system or replacement parts elsewhere? We'll match or beat it—no hassle, no gimmicks.
Simply provide:
