The catalog lists: ATS DWS-15, ATS DWS-15C, ATS DWS-25, ATS DWS-30C, ATS DWS-50C, ATS DWS-5C, ATS DWS-8C, ATS DWSW-15, Ideal Horizons IH-10S. Confirm the exact model or part number on your equipment before ordering 15-0423 quartz sleeve.
Q:
What does the 15-0423 quartz sleeve do?
A:
The quartz sleeve isolates the UV lamp from chamber water while allowing UV energy to pass through. The correct sleeve dimensions and open/closed-end design must match the installed chamber.
Q:
When should the quartz sleeve be replaced?
A:
Replace it if cracked, chipped, clouded, etched, or no longer restorable during maintenance. Many sleeves are replaced around every 24 months, subject to the equipment manual and water conditions.
Q:
Can mineral scale be removed from the sleeve?
A:
Light deposits can often be removed with the manufacturer-approved method. Rinse thoroughly and replace the sleeve if clouding or deposits remain.
Q:
Should the sleeve O-rings be inspected?
A:
Yes. Replace seals that are cut, flattened, stretched, or brittle, and use only a light coating of food-grade silicone lubricant if the manual directs it.
Q:
What installation mistakes can damage a quartz sleeve?
A:
Forcing the sleeve, uneven retaining pressure, grit on sealing surfaces, and pinched O-rings can cause cracks or leaks. Shut off water and power, relieve pressure, and handle quartz with clean gloves.
15-0423 UV Quartz Sleeve for Aquafine CSL and RBE Systems