★★★★★ Serving 60,000+ customers with 6,200+ five star reviews.
FILTER FINDER

What system do you have?

Brand
Select your brand...
Model
Select your model...

G48T5L Replacement Ultraviolet UV Lamp 05-1334-R

Q&As

G48T5L Replacement Ultraviolet UV Lamp 05-1334-R

Q&As
Part Number: 05-1334-R
Alt Part Number:
05-1334-R ATS1-1149 12013 LP4535 ...
close
G48T5L
High output UV replacement lamp for Atlantic Ultraviolet systems ensuring consistent disinfection performance. Read More
This Item Fits Select Systems
See List
$97.50$121.88
IN STOCK

Description

The Atlantic Ultraviolet G48T5L UV replacement lamp is a replacement lamp for the Atlantic Ultraviolet MightyPure MP49C and the Sanitron S50B and S50C systems; as well as a generic replacement lamp for many other UV systems. The G48T5L is a 1 single-pin double-ended (B1) lamp that is 45 inches long (1148mm). The lamp operates at 55 watts with a quartz outside diameter of 15mm. Replace this UV lamp every 12 months or 10,000 to maintain proper system efficacy.

Specs
  • 1 Single Pin Double Ended B1 Lamp
  • 55 Watts
  • Length: 45"/1148mm
  • Replace every 12 months
Features
For use with Atlantic Ultraviolet MightyPure MP49C and the Sanitron S50B and S50C systems.
This Item Fits These Select Systems

Q:

Which systems use the G48T5L / 05-1334-R?

A:

The catalog lists: G48T5L, Mighty Pure MP49C, Sanitron S50B, Sanitron S50C. Confirm the exact model and part number on your equipment before ordering G48T5L / 05-1334-R.

Q:

How often should the G48T5L / 05-1334-R be replaced?

A:

Replace it every 12 months, even if it still lights. Visible light does not show whether UV output remains at the designed level.

Q:

Does this listing include a quartz sleeve?

A:

No. This is the replacement lamp only unless the package contents explicitly say otherwise. Inspect the sleeve and seals during lamp service.

Q:

What should I do before changing the lamp?

A:

Turn off power, shut off water if the chamber will be opened, relieve pressure, and allow the lamp to cool. Handle the new lamp with clean gloves.

Q:

Why must the exact lamp part number match?

A:

Lamp length, base, wattage, and output must match the controller and chamber. This lamp is approximately 45 inches long, 55 watts, 15 mm in diameter, and uses a single-pin double-ended base.

Q:

What should I check after installation?

A:

Confirm connector alignment, controller operation, lamp-life reset, sleeve condition, and leak-free seals before returning the system to normal operation.