Automatic deliveries and charges at your selected frequency. Skip, reschedule, or cancel through your subscription account. View subscription details.
$97.50$121.88
IN STOCK
Case Discount:
Description
The Atlantic Ultraviolet G48T5L UV replacement lamp is a replacement lamp for the Atlantic Ultraviolet MightyPure MP49C and the Sanitron S50B and S50C systems; as well as a generic replacement lamp for many other UV systems. The G48T5L is a 1 single-pin double-ended (B1) lamp that is 45 inches long (1148mm). The lamp operates at 55 watts with a quartz outside diameter of 15mm. Replace this UV lamp every 12 months or 10,000 to maintain proper system efficacy.
Specs
1 Single Pin Double Ended B1 Lamp
55 Watts
Length: 45"/1148mm
Replace every 12 months
Features
For use with Atlantic Ultraviolet MightyPure MP49C and the Sanitron S50B and S50C systems.
The catalog lists: G48T5L, Mighty Pure MP49C, Sanitron S50B, Sanitron S50C. Confirm the exact model and part number on your equipment before ordering G48T5L / 05-1334-R.
Q:
How often should the G48T5L / 05-1334-R be replaced?
A:
Replace it every 12 months, even if it still lights. Visible light does not show whether UV output remains at the designed level.
Q:
Does this listing include a quartz sleeve?
A:
No. This is the replacement lamp only unless the package contents explicitly say otherwise. Inspect the sleeve and seals during lamp service.
Q:
What should I do before changing the lamp?
A:
Turn off power, shut off water if the chamber will be opened, relieve pressure, and allow the lamp to cool. Handle the new lamp with clean gloves.
Q:
Why must the exact lamp part number match?
A:
Lamp length, base, wattage, and output must match the controller and chamber. This lamp is approximately 45 inches long, 55 watts, 15 mm in diameter, and uses a single-pin double-ended base.
Q:
What should I check after installation?
A:
Confirm connector alignment, controller operation, lamp-life reset, sleeve condition, and leak-free seals before returning the system to normal operation.