Luminor LB4-021 Blackcomb 4.1 UV Water Treatment System 2 GPM
Luminor LB4-021 Blackcomb 4.1 UV Water Treatment System 2 GPM
Description
The Luminor LB4-021 BLACKCOMB 4.1 is a compact UV water disinfection system rated at 2 GPM (7.6 L/min) at a UV dose of 30 mJ/cm² and 95% UV transmittance. It uses an 8-watt UV lamp in a polished 304 stainless steel chamber (2.5 x 10.3 inches) with 1/2-inch FNPT connections, which suits single-faucet, cottage and other low-flow applications. The BLACKCOMB 4.1 controller shows lamp status with a tri-colour LED and remaining lamp life on a 4-digit display, with audible and visual alarms.
Flow rate by UV dose
- 2 GPM at 30 mJ/cm² (Luminor rating, 95% UVT)
- 4 GPM at 16 mJ/cm²
- 1.6 GPM at 40 mJ/cm²
How it alerts you
The LED is green when the lamp is on and within its rated life, turns yellow 30 days before the lamp expires (with a chirp in the last 7 days), and turns red with a buzzer when the lamp fails or expires. The controller reports lamp status; it does not by itself confirm the water is safe to drink, so Luminor recommends testing your water for microbiological contaminants regularly.
Water quality requirements
- Luminor strongly recommends a 5-micron sediment prefilter before the UV system
- Hardness under 7 gpg (soften above this); pH 6.5-8.5
- Iron under 0.3 ppm, manganese under 0.05 ppm, tannins under 0.1 ppm, turbidity under 1 NTU
- UV transmittance above 85% (contact Luminor below 80% for pretreatment advice)
Specifications
- Model: LB4-021 (BLACKCOMB 4.1)
- Flow: 2 GPM at 30 mJ/cm², 95% UVT
- Connections: 1/2-inch FNPT
- Lamp: 8 W, RL-210; power draw 14 W
- Electrical: 90-265V, 50/60 Hz; North American NEMA 5-15 plug ("1" suffix)
- Chamber: polished 304 stainless steel, 2.5 x 10.3 inches
- Operating pressure: 10-150 psi; water temperature: 36-149°F (2-65°C)
- UPC: 880027048182
Maintenance and replacement parts
- UV lamp: RL-210. Replace every 12 months (standard lamps are rated about 9,000 hours).
- Quartz sleeve: RQ-210. Clean every 6-12 months and replace every 24 months, or sooner if scaled, cloudy or damaged.
- Lamp and sleeve kit: RLQ-210
BLACKCOMB 4.1 systems do not support a UV sensor or add-on modules; choose a BLACKCOMB 5.1 or 6.1 if you need UV monitoring. No temperature relief valve is offered for the 2 GPM size.
Warranty Luminor limited warranty: 10 years on the stainless steel reactor, 3 years on the controller, and 1 year on UV lamps, UV sensors and quartz sleeves.
- Flow rating: 2 GPM at 30 mJ/cm² and 95% UV transmittance
- 1/2-inch FNPT connections
- 90–265V, 50/60 Hz. North American power-cord configuration.
- Replacement UV lamp: RL-210
- Replacement quartz sleeve: RQ-210