Luminor LBH6-251A Blackcomb-HO 6.1 UV System NSF Class A 7.9 GPM
Luminor LBH6-251A Blackcomb-HO 6.1 UV System NSF Class A 7.9 GPM
Description
The Luminor LBH6-251A BLACKCOMB-HO 6.1 is a UV water disinfection system certified to NSF/ANSI 55 Class A. With its built-in flow restrictor it is rated at 7.9 GPM (29.9 L/min) at a UV dose of 40 mJ/cm² and 70% UV transmittance. Class A systems are designed to disinfect microbiologically contaminated water that meets all other public health standards, making the LBH6-251A a fit for private wells and other untreated supplies. It pairs a 67-watt high-output UV lamp with a 316L stainless steel chamber and a UV intensity sensor that continuously monitors the UV reaching the water.
How it works and alerts you
The full-colour LCD controller shows remaining lamp life, system status and fault messages. It gives a yellow caution 30 days before the lamp expires, audible and visual alarms for lamp failure or low UV, and a service reminder every 6 months. Its Infinite Expandability Port (IEP) accepts optional Luminor modules: MOD-SOL solenoid control, MOD-420 4-20 mA output, MOD-RAM remote alarm, the MOD-SHERPA wireless monitor and the LFM ultrasonic flow meter.
Why the rating is 7.9 GPM, not 25 GPM
The standard LBH6-251 is rated 25 GPM at 30 mJ/cm² and 95% UVT. The NSF Class A rating is stricter: it requires a higher dose (40 mJ/cm²) at lower water clarity (70% UVT), and the integral flow restrictor holds flow to the certified 7.9 GPM. Do not remove the flow restrictor; the certification depends on it.
Water quality requirements
- Install on visually clear water; Luminor strongly recommends a 5-micron sediment prefilter
- Hardness under 7 gpg (soften above this), pH 6.5-8.5
- Iron under 0.3 ppm, manganese under 0.05 ppm, tannins under 0.1 ppm, turbidity under 1 NTU
- Not for converting wastewater or raw sewage to drinking water
Specifications
- Certification: NSF/ANSI 55 Class A
- Certified flow: 7.9 GPM (29.9 L/min) at 40 mJ/cm², 70% UVT
- Connections: 1-inch MNPT
- Lamp: 67 W high output, RL-600HO; power draw 73 W (72 W at 230V)
- Electrical: 90-265V, 50/60 Hz; North American NEMA 5-15 plug ("1" suffix)
- Chamber: 316L stainless steel, 3.5 x 26.9 inches
- Operating pressure: 10-150 psi; water temperature: 36-149°F (2-65°C)
- UPC: 880027022243
Maintenance and replacement parts
- UV lamp: RL-600HO. Replace every 12 months (rated 10,000 hours).
- Quartz sleeve: RQ-600. Clean every 6-12 months and replace every 24 months, or sooner if scaled, cloudy or damaged.
- Lamp and sleeve kit: RLQ-600HO
- UV sensor: clean every 6-12 months and replace every 5 years; sensor O-ring 310120
- NSF O-ring: 300070
- Optional: 130014 LUMI-cool fan
Warranty Luminor limited warranty: 10 years on the stainless steel reactor, 3 years on the controller, and 1 year on UV lamps, UV sensors and quartz sleeves.
- Flow rating: 7.9 GPM at 40 mJ/cm² and 70% UV transmittance
- 1-inch MNPT connections
- 90–265V, 50/60 Hz. North American power-cord configuration.
- Replacement UV lamp: RL-600HO
- Replacement quartz sleeve: RQ-600