Part Number: RL-850
Replacement UV lamp with reset key restores 9000 hour output for LB4 201 and LB5 201 whole home systems. Read More
This Item Fits Select Systems
See List
$132.66$165.83
IN STOCK
Receive a 15% bulk discount   on orders of 12 or more
Description

The RL-850 is a genuine Luminor replacement UV lamp and lamp key for LUMINOR BLACKCOMB LB4-201, LB5-201, and LB6-201 UV water treatment systems. It is an authentic Luminor part, not a compatible aftermarket substitute, so it drops in and treats water the way your system was originally tested and certified to perform.

The lamp is rated for 9,000 hours of use, about 12 months of continuous operation. UV-C output weakens gradually over the lamp's life, so Luminor recommends replacing it every 12 months or after 9,000 hours, whichever comes first, to keep UV output where the system needs it.

Why a genuine Luminor lamp matters

Luminor tests and certifies its UV systems as a complete unit: lamp, chamber, and sleeve together. An authentic RL-850 keeps your system performing the way it was certified. A non-Luminor lamp voids the system's NSF/ANSI 55 certification and can affect your warranty coverage if a problem comes up later.

Fits these Luminor BLACKCOMB systems

All three models above share the same "-201" flow rating, rated at 21 GPM, and use the RL-850.

Complete your replacement The RL-850 is the lamp only. For the full replacement:

Specs
  • Replace every 12 months or 9,000 hours of use
  • Length: 33.5" (850mm)
  • Power: 42 Watts
Features
Includes Lamp Key (works for LUMINOR Branded Systems Only)
For all LUMINOR BLACKCOMB 4.1 LB4-201, 5.1 LB5-201, 6.1 LB6-201 models
Helpful Info & Downloads
Downloads

Watch this step-by-step video to learn how to replace a quartz sleeve on a Luminor UV water treatment system for optimal UV disinfection performance. ESP Water Products, an authorized Luminor dealer, offers genuine Luminor UV systems and replacement parts.

Overall rating: 4.3333335 / 5 from 6 reviews.

AI Generated Review Summary

Summary topics

Review topics: [].

Review highlights

Reviews

wont buy from esp again

"I ordered my bulb in april, when i went to install it in may the bulb was broken in two pieces, they sent a new one, it burned out in 2-3 hours, the 3rd bulb arrived and worked but it had been so lond without a good luminor RL-850 UV bulb i had to disinfect the whole system. I asked them to expedite th ebulb and they said no. . ."

Judy H. (1/5)

Glad I Found This Site

"I been using the OEM site to order replacement lamps. These lamps are cheaper but with the same quality."

Mike F. (5/5)

It wirksf

"It wirksf"

Michael B. (5/5)

Great shop, very easy buying process.

"The whole shopping experience was fast and easy, the description and photos very clear and payment process quick. Shipping was faster than expected and packaging was perfect."

Alexander L. (5/5)

Awesome Customer Service

"ESP went above and beyond to adjust produ t delivery to meet my travelling schedule."

Michael B. (5/5)

Easy to install. The packaging

"Easy to install. The packaging protected the item well!"

Otto S. (5/5)

Q&A

Overall rating: 4.3333335 / 5 from 6 reviews.

AI Generated Review Summary

Summary topics

Review topics: [].

Review highlights

Reviews

wont buy from esp again

"I ordered my bulb in april, when i went to install it in may the bulb was broken in two pieces, they sent a new one, it burned out in 2-3 hours, the 3rd bulb arrived and worked but it had been so lond without a good luminor RL-850 UV bulb i had to disinfect the whole system. I asked them to expedite th ebulb and they said no. . ."

Judy H. (1/5)

Glad I Found This Site

"I been using the OEM site to order replacement lamps. These lamps are cheaper but with the same quality."

Mike F. (5/5)

It wirksf

"It wirksf"

Michael B. (5/5)

Great shop, very easy buying process.

"The whole shopping experience was fast and easy, the description and photos very clear and payment process quick. Shipping was faster than expected and packaging was perfect."

Alexander L. (5/5)

Awesome Customer Service

"ESP went above and beyond to adjust produ t delivery to meet my travelling schedule."

Michael B. (5/5)

Easy to install. The packaging

"Easy to install. The packaging protected the item well!"

Otto S. (5/5)

Q&A

Q:

How do I know if the RL-850 is the right lamp for my system?

A:

Check the model number on your system's nameplate. The RL-850 fits LB4-201, LB5-201, and LB6-201. If your model ends in a different number, like -101, -151, or -061, you need a different lamp.

Q:

Is a 21 GPM system (LB4-201, LB5-201, LB6-201) big enough for my house?

A:

Yes, for the vast majority of homes. As a sizing reference, ESP recommends at least 6 GPM for a 1-bathroom home, 9 GPM for 2 bathrooms, 12 GPM for 3, 15 GPM for 4, and 18 GPM for 5, and it's better to oversize than undersize. At 21 GPM, the LB4/LB5/LB6-201 covers the largest homes on that scale with room to spare. For flow needs beyond that (large commercial applications), contact ESP directly since those are sized on a case-by-case basis.

Q:

I installed a new RL-850 and now the system says "Lamp Incorrect." What's wrong?

A:

This alarm means the lamp key doesn't match what your chamber requires. Compare the part number on the lamp key to the silver label on the UV chamber. If they don't match, you have the wrong lamp; the RL-850 is for the standard-output LB4/LB5/LB6-201 systems listed above, and BLACKCOMB-HO systems use an entirely different model and lamp lineup. If the numbers do match and the alarm persists, contact Luminor support.

Q:

How do I reset the lamp timer after installing the RL-850?

A:

On a 4.1 controller (4-digit LED display), press and hold the front button until the display cycles through rSt3, rSt2, rSt1 and beeps. On a 5.1 controller (LCD display with lamp key), unplug the controller, remove the old lamp key, insert the new lamp's key, then plug it back in. Either way, the display should return to showing full lamp life remaining; if it doesn't, contact Luminor support.

Q:

Will a non-Luminor replacement lamp work in my BLACKCOMB system?

A:

It may physically fit, but Luminor systems are NSF/ANSI 55 certified as a complete lamp-and-system unit. A non-Luminor lamp voids that certification and can affect your warranty if an issue comes up.