This lamp is the replacement lamp for obsolete VIQUA Sterilight SPV-6, SP320-HO, SC-320 and SCM-320 Series UV systems. It is extremely important to replace this lamp every 12 months to maintain proper system efficacy.
Why using a genuine VIQUA lamp is important: VIQUA UV systems and lamps are tested and certified as a complete unit. Using an authentic VIQUA lamp ensures proper system performance and water treatment. This video explains the 5 risks of non-VIQUA aftermarket lamps and how to identify authentic VIQUA lamps.
NOTE: Using non-VIQUA lamps voids all UV system certifications and may compromise your warranty should an issue arise.
Overall rating: 5.0 / 5 from 2 reviews.
Review topics: [].
"Perfect fit, works perfectly on the first try, no issues. Fast shipping and they had exactly what I needed. Back to good water."
"Good supplier & great customer service. Competitively priced products. Quick delivery."
Q:
Which systems use the VIQUA S320RL-HO?
A:
The catalog lists: S320RL-HO, SPV-6, SP320-HO, SC-320. Confirm the exact model and part number on your equipment before ordering VIQUA S320RL-HO.
Q:
How often should the VIQUA S320RL-HO be replaced?
A:
Replace it every 12 months, even if it still lights. UV output declines with operating time, so visible light does not confirm expected treatment output.
Q:
Does this listing include a quartz sleeve?
A:
No. This is the replacement lamp only unless package contents explicitly state otherwise. Inspect the sleeve and seals during lamp service.
Q:
Why is the exact lamp part number important?
A:
Lamp length, base, wattage, and UV output must match the controller and chamber. This high-output lamp is for the catalog-listed obsolete Sterilight systems.
Q:
What should I do before changing the lamp?
A:
Turn off power, shut off water if the chamber will be opened, relieve pressure, allow the lamp to cool, and handle the replacement with clean gloves.
Q:
What should I check after installation?
A:
Confirm connector alignment, controller operation, lamp-life reset, sleeve condition, and leak-free seals before returning the system to normal operation.