VIQUA K+ (K Plus) systems include all the features of the K Model system plus the advanced UV sensor for enhanced system performance tracking. The VIQUA K+ features an amalgam lamp that provides higher strength and up to 2 years of lamp life. The K+ is designed for 80 GPM flow rates and is capable of 100-240V, 50-60Hz.
To request international electrical plug types “F” (Europe), “G” (UK), and “I” (Australia) be included with your system at no charge, please email customer support, after ordering.
Specs
Flow Rate: 80 Gallons Per Minute
Application: Point-of-Entry
Power: 100-240V 50-60Hz 230W N. American Plug
Chamber Dimensions: 41" x 4"
Inlet Dimensions: 2" MPT
Outlet Dimensions: 2" MPT
Electrical Plug Types Available: B – North & Central America, Japan (NEMA 5-25P) F – Europe, Brazil, Russia (CEE 7/7)
Features
Monitors UV light intensity for proper UV dose
Long two-year UV lamp life for less maintenance
Counts down the days until UV lamp is due for replacement
LED lights for system status monitoring
Integrates with optional solenoid valve for automatic water shut-off when system errors occur
What flow rate is the VIQUA K+ 660002-R designed for?
A:
VIQUA lists up to 80 GPM at a 30 mJ/cm² UV dose. The official specifications also list 60 GPM at 40 mJ/cm² and 120 GPM at 16 mJ/cm², so size the system to the required treatment target and peak flow.
Q:
What plumbing connection does the K+ use?
A:
It uses 2-inch MNPT inlet and outlet connections. Allow room for shutoff valves, service clearance, and the controller and fan.
Q:
Does the K+ include UV performance monitoring?
A:
Yes. The K+ includes a UV sensor for real-time performance feedback, plus a controller with lamp-life display and audible reminders.
Q:
How often is the lamp replaced?
A:
The high-output amalgam lamp is rated for up to two years. Follow controller hours and alarms, and service the quartz sleeve and seals at the same time.
Q:
What electrical supply does 660002-R accept?
A:
It accepts 100–240 volts at 50–60 Hz. Confirm the supplied plug, grounding, and local electrical requirements.
Q:
What water conditions and prefiltration should I verify?
A:
Size pretreatment to keep sediment and other water-quality parameters within the VIQUA specification. UV treats water with light and does not remove sediment, hardness, or dissolved solids.